logo

ASCO Solenoid Valves and Samson 3730-3 Electropneumatic HART Valve Positioner Valve Controller

1
MOQ
1900 dollars
가격
ASCO Solenoid Valves and Samson 3730-3 Electropneumatic HART Valve Positioner Valve Controller
풍모 갤러리 제품 설명 평점 및 리뷰 따옴표를 요구하십시오
풍모
제품 사양
부하 저항: 8.2V 이하
히스테리시스: ≤ 0.3%
감광도: ≤ 0.1 %
허용 주변 온도: -20 ~ +80 °C, 금속 케이블 글랜드 포함 -40 ~ +80 °C
출력 신호: 4~20mA
공급 전압: 12~30V DC
강조하다:

ASCO solenoid control valves

,

Samson 3730-3 HART valve positioner

,

electropneumatic valve controller

기본 정보
원래 장소: 중국
브랜드 이름: Samson
모델 번호: 3730-3
결제 및 배송 조건
포장 세부 사항: 카톤 + 목재 상자 + 보호 포장
배달 시간: 70 일
지불 조건: 티/티
공급 능력: 매년마다 600 유닛
제품 설명
Product Overview

Engineered by SAMSON, the Type 3730-3 electropneumatic positioner integrates a travel sensor, i/p converter, air booster, and microcontroller for high-precision valve control. It compares valve travel/angle to a 4-20 mA signal, outputting pneumatic pressure to actuators. Supports HART for communication and diagnostics, with firmware updates enhancing functionality like automatic option detection and extended configuration periods.

Key Features
  • Control Mechanism: PD controller with A/D conversion for real-time deviation correction.
  • Pneumatic Optimization: Volume restriction Q for actuator size adaptation; intermediate flow regulator for stable booster operation.
  • Diagnostics Integration: EXPERT+ for predictive maintenance via TROVIS-VIEW or DTM.
  • Safety Features: Fail-safe venting via optional solenoid; signal pressure limiting.
  • Communication: Serial SSP interface and HART (Rev 5/6) for parameter tuning.
  • Customizability: User-defined characteristics (e.g., butterfly/rotary plug valves).
  • Hazardous Area Ready: IP 65 rating, multiple explosion protections.
Technical Specifications
Parameter Details
Load Impedance ≤8.2 V (410 Ω at 20 mA)
Air Delivery (Pressurized/Vented) Δp=6 bar: 8.5/14.0 m³/h; Δp=1.4 bar: 3.0/4.5 m³/h
Influences Temperature: ≤0.15%/10K; Vibration: ≤0.25% up to 2000 Hz/4g
Explosion Protection EEx ia IIC T6, EEx nA II T6, IECEx, FM/CSA IS/NI
Communication HART impedance: Receive 350-450 Ω, Send ~155 Ω
Binary Contacts No Ex: R=348 Ω (conductive); Ex: ≥2.1 mA / ≤1.2 mA
Software Requirements TROVIS-VIEW module 3730-3; HART DTM for FDT frames
Applications

Optimized for industrial control in environments with variable transit times or harsh conditions, including throttling in pipelines and use with external sensors for remote setups. Applicable to IEC 60534-6 linear actuators or VDI/VDE 3845 rotary ones, often in petrochemical or power generation for flow regulation.

Frequently Asked Questions
  1. What causes 'No emergency mode' (Code 76)? Indicates lack of fallback during faults; check firmware and settings.
  2. How to perform zero calibration? Access via Code 6 after initialization; tracks calibrations since last init.
  3. Can transit times be limited? Yes, via Codes 21/22 up to 240 s to prevent rapid actuator engagement.
  4. What if initialization fails? Reset to defaults (Code 36) or check lever/pin position.
  5. How to integrate with PLC? Binary inputs per EN 61131-2, P_max=400 mW.
Contact Us

Phone/WeChat/WhatsApp: +8613916209596

Email: svetama@gbsxj.com

Related Products
  • Type 3730-31000000400000009.03: Specific variant with HART.
  • TROVIS 3730-3: Upgraded smart positioner.
  • Type 3730-4: With PROFIBUS-PA.
  • Type 3731-3: For explosive atmospheres.
  • Accessories: Type 3710 Reversing Amplifier.
평점 및 리뷰

전체 등급

5.0
이 공급업체에 대한 50개의 리뷰를 기반으로 합니다.

등급 스냅샷

다음은 모든 평점의 분포입니다.
5 별
0%
4 별
0%
3 별
0%
2 별
0%
1 별
0%

모든 리뷰

F
FLOWSERVE MARK ONE Linear Globe Angle Control Valve Spring Cylinder Valve Pneumatic Actuator
Switzerland Dec 1.2025
great price and fast delivery
추천된 제품
우리와 연락하기
담당자 : Mr. Edward Zhao
전화 번호 : +8615000725058
남은 문자(20/3000)