Ametek Thermox WDG-V WDG-IV UOP UOP/RP Continuous Catalyst Regeneration Oxygen Analyzer for UOP Process

1
MOQ
US $99999.00 - 105000.00/ Unit
가격
Ametek Thermox WDG-V WDG-IV UOP UOP/RP Continuous Catalyst Regeneration Oxygen Analyzer for UOP Process
풍모 갤러리 제품 설명 따옴표를 요구하십시오
풍모
제품 사양
출력 범위: 0-1%에서 0-100%
연락처 등급: 0.5A, 30V, 10VA MAX. 비 유인 부하, AC 또는 DC
울로 둘러싼 땅: IP65(NEMA 4X)
대기 온도: -20 ~ 55 ° C (-4 ~ 131 ° F)
정확성: 측정 된 값의 ± 0.75% 또는 ± 0.05% 산소가 더 큽니다.
산출: 4-20 MA / HART
기본 정보
브랜드 이름: Ametek
모델 번호: WDG-V UOP/WDG-IV UOP
결제 및 배송 조건
포장 세부 사항: 요청대로
배달 시간: 60일
지불 조건: 티/티
공급 능력: 연간 50개 단위
제품 설명
Ametek WDG-V UOP & WDG-IV UOP

The oxygen analyzers that every UOP CCR Platforming unit has on the regen tower stack

Why UOP Only Allows These Two Models

When you license a UOP CCR Platforming process, the P&ID already shows an Ametek WDG analyzer on the regenerator flue gas. That’s it – no alternatives. The reason is simple: the sensor sits directly in 650–720 °C flue gas full of chlorine, catalyst dust and water. Normal “cold-wall" analyzers die in weeks. The WDG-V UOP (newer) and WDG-IV UOP (old workhorse) are built different – the zirconia cell is close-coupled, the whole probe is heated to 300 °C, and the blowback actually works. Most units get a cell change every 4–6 years and keep running.

Stuff That Actually Matters on a CCR Unit
  • Close-coupled sensor – no sample line to plug with cat fines
  • Whole probe heated to 300 °C – no acid condensation
  • Real automatic blowback every few hours – keeps the filter clean
  • WDG-V UOP has color touchscreen and USB data log
  • WDG-IV UOP still preferred by old-timers because it never breaks
  • Both give 0–1% and 0–10% O₂ ranges for burn and combustion control
Quick Numbers
Measurement 0–1% / 0–10% O₂ (field selectable)
Process temperature up to 900 °C (normal 650–720 °C)
Response time T90 less than 10 seconds
Output 4–20 mA isolated, Modbus RTU, HART on WDG-V
Power 115/230 VAC, about 500 W with heater
Probe length 0.5 m – 3 m (most plants use 1.5 m)
Approvals Class I Div 2, ATEX Zone 2 standard
Where They Live
  • UOP CCR Platforming regenerator flue gas
  • Some Axens and ExxonMobil CCR units also specify them
  • Chlorine-rich combustion zones in catalyst plants
Questions We Hear on Every Turnaround

Q: How often do I change the zirconia cell?
A: Usually 4–6 years, some plants hit 8 years.

Q: Can I just buy any zirconia analyzer?
A: No – UOP will reject it during HAZOP if it’s not WDG-IV/V UOP.

Q: Spare parts for the old WDG-IV?
A: Still made in USA, next-day ship from stock.

Contact Us

Ametek Thermox
Email: edwardzhao@gbsxj.com

Phone/WhatsApp/WeChat: +8615000725058

Other Stuff We Sell for Refineries
  • WDG-V Zone 1 version for worse locations
  • WDG-Insitu for boiler combustion
  • Replacement cells and filters for old WDG-IV